The bar or component to be tested is
magnetised by passing a heavy current through
it or by making it the core of a coil through
which a heavy current is passed. Cracks or
inclusions cause the magnetic flux to break the
surface forming free magnetic poles. When the
component is sprayed with a suspension of
finely divided magnetic particles they collect at
the free poles to visibly show the presence of
defects.